6.2  Payload Bay Connections
NOTE: Standard connectors, such as audio, are not covered here. This includes all
of the connectors on the right side of the core, shown in the following figure:
Connection
User LAN
Aux Sensors
RS-232 x 2
CAN Bus B
Digital I/O (HDB44F)
Analog I/O
60
Digital Ant1 Ant2
Audio Out
Audio In
Audio Out
Figure 6-1. Right Side of the Core

LD Platform Core Front, Upper

Figure 6-2. Front Upper Core
Type
RJ45
General Ethernet, Auto-MDIX, shielded
HDB15M
Low front and optional side lasers
DB9M
Port 1 and Port 2, general use
DB9F
Consult your local Omron Support for use.
HDB44F
16 digital inputs, in 4 banks of 4. Each bank can be
wired as active high or active low depending on the
connection of the BANK# terminal.
V
range for each input is 0 to 30 V. The input is ON
IN
when V
IN
16 digital outputs, protected low-side drivers. These
outputs should be wired to positive voltage through
the load. Output is open when OFF and grounded
when ON. Each open-drain output is capable of sink-
ing 500 mA. May be used with loads connected to
VBAT, AUX_20V, _12V, or _5V. You must stay
within the allowed current capacity of the VBAT or
AUX power supplies.
HDB15M
General use
LD Platform OEM User's Guide
Description
> 4 V, OFF when V
< 1.3 V.
IN
11970-000 Rev H1