Condition/Problem
Resistance does not change
(machine turns on and oper-
ates)
Incline does not adjust (machine
turns on and operates)
Console shuts off (enters sleep
mode) while in use
Fan will not turn on or will not
turn off
Fan will not turn on, but Console
operates
Things to Check
Check Console
Check data cable integrity
Check data cable connections/
orientation
Resistance handlebar
connection
Check Servo Motor (requires
shroud removal)
MCB (requires shroud removal)
Check Console
Incline handlebar connection
Lower and Upper I/O Cables
(requires shroud removal)
Incline Adjuster Assembly
(requires shroud removal)
Check electrical (wall) outlet
Check connection at front of unit Connection should be secure and undamaged. Replace adapter or connec-
Check data cable integrity
Check data cable
connections/orientation
Reset machine
Check magnet position (requires
shroud removal)
Check Speed Sensor (requires
shroud removal)
Check data cable integrity
Check data cable
connections/orientation
Reset machine
Check for blockage of fan
Check for visual sign that Console is damaged. Replace Console if damaged.
All wires in cable should be intact. If any are visibly crimped or cut, replace
cable.
Be sure cable is connected securely and oriented properly. Reseat all con-
nections. Small latch on connector should line up and snap into place.
Be sure cable from right Upper Handlebar and cables to Console are secure
and undamaged.
If magnets move, adjust until they are within the proper range. Replace
Servo Motor if not functioning properly.
Replace MCB.
If the above steps do not resolve the problem, contact Customer Care for
further assistance.
Check for visual sign that Console is damaged. Replace Console if damaged.
Be sure cable from left Upper Handlebar and cables to Console are secure
and undamaged.
All wires in the cables should be intact. If any are cut or crimped, replace
cable.
Be sure Incline Adjuster Assembly is attached to Incline Motor drive screw.
If the above steps do not resolve the problem, contact Customer Care for
further assistance.
Make sure unit is plugged into a functioning wall outlet.
tion at unit if either are damaged.
All wires in the cable should be intact. If any are cut or crimped, replace
cable.
Be sure cable is connected securely and oriented properly. Small latch on
connector should line up and snap into place.
Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet.
Magnet should be in place on pulley.
Speed sensor should be aligned with magnet and connected to data cable.
Realign sensor if necessary. Replace if there is any damage to the sensor or
the connecting wire.
All wires in cable should be intact. If any are cut or crimped, replace cable.
Be sure cable is connected securely and oriented properly. Small latch on
connector should line up and snap into place.
Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet.
Unplug unit from electrical outlet for 5 minutes. Remove material from fan. If
necessary, detach the Console to help with removal. Replace the Console if
unable to remove blockage.
14
Solution

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bxe216