5. PARAMETERS
No./symbol/
Setting
name
digit
PC72
_ _ _ x Modbus RTU communication endian selection
*COPG
This digit can be used only when Modbus RTU is set.
Function
0: Standard endian
selection C-G
1: Big endian
Endian indicates the order of data with the unit of 2 bytes.
For example, the following shows the order of 4-byte data "12345678h".
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _

5.2.2 Extension setting 3 parameters ([Pr. PF_ _ ])

No./symbol/
Setting
name
digit
PF45
_ _ _ x Protocol parity selection
*FOP12
This digit can be used only when Modbus RTU is set.
Function
0: Even parity (stop bit length of 1 bit)
selection F-12
1: Odd parity (stop bit length of 1 bit)
2: No parity (stop bit length of 2 bits)
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _
PF46
Set the time-out period for Modbus RTU communication protocol.
MIC
When "0" is set, the time-out is not checked.
This parameter can be used only when Modbus RTU is set.
Modbus RTU
communication
time out
Setting range: 0 to 60
selection
Order of transmitting/
Standard endian
receiving byte
1
2
3
4
Function
Big endian
56h
12h
78h
34h
12h
56h
34h
78h
Function
5 - 7
Initial
value
[unit]
0h
0h
0h
0h
Initial
value
[unit]
0h
0h
0h
0h
0
[s]