5. PARAMETERS
No./symbol/
Setting
name
digit
PN27
Set the 4th octet of the IP address of the network device allowed to be connected in
decimal.
*IPAF4
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
IP address
disabled.
filter 4
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
PN28
Set a value for the 2nd octet range of the IP address of the network device allowed
to be connected. The range for the IP address of the network device allowed to be
*IPFR2
connected is between [Pr. PN25] and [Pr. PN28].
IP address
Set a value in decimal.
filter 2 range
specification
Setting "256" disables the function.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 256
PN29
Set a value for the 3rd octet range of the IP address of the network device allowed to
be connected. The range for the IP address of the network device allowed to be
*IPFR3
connected is between [Pr. PN26] and [Pr. PN29].
IP address
Set a value in decimal.
filter 3 range
specification
Setting "256" disables the function.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 256
PN30
Set a value for the 4th octet range of the IP address of the network device allowed to
be connected. The range for the IP address of the network device allowed to be
*IPFR4
connected is between [Pr. PN27] and [Pr. PN30].
IP address
Set a value in decimal.
filter 4 range
specification
Setting "256" disables the function.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 256
PN31
Set the 1st octet of the IP address of the network device allowed to be connected in
decimal.
*IPOA1
When [Pr. PN31] to [Pr. PN34] are all set to "0", the operation specification IP
Operation
address function is disabled.
specification
IP address 1
This parameter cannot be used when Modbus RTU is set.
When this function is enabled with CC-Link IE Field Network Basic communication,
the servo amplifier allows the following data 1) to 3) to be imported only if the IP
address of the master station (external device) matches with the operation
specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
When this function is enabled with Modbus/TCP communication, the servo amplifier
allows the following data 4) to be imported only if the IP address of the client
(external device) matches with the operation specification IP address. If they are
mismatched, the data is discarded.
4) Modbus/TCP function code 10h
Monitoring, parameter setting, and test operation can be executed via Ethernet when
the IP addresses of a personal computer (MR Configurator2) and GOT are within the
range of the operation specification IP address. When they are out of the range,
communication to the servo amplifier cannot be established.
Setting range: 0 to 255