No./symbol/
Setting
name
digit
PN19
Set the 1st octet of the default gateway in decimal.
*DGW1
Set the default gateway assigned by the network administrator.
Default
The default gateway can also be changed simultaneously by the SLMP command
gateway
(IPAdressSet).
setting 1
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
PN20
Set the 2nd octet of the default gateway in decimal.
*DGW2
Set the default gateway assigned by the network administrator.
Default
The default gateway can also be changed simultaneously by the SLMP command
gateway
(IPAdressSet).
setting 2
This parameter cannot be used when Modbus RTU is set.
Setting range 0 to 255
PN21
Set the 3rd octet of the default gateway in decimal.
*DGW3
Set the default gateway assigned by the network administrator.
Default
The default gateway can also be changed simultaneously by the SLMP command
gateway
(IPAdressSet).
setting 3
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
PN22
Set the 4th octet of the default gateway in decimal.
*DGW4
Set the default gateway assigned by the network administrator.
Default
The default gateway can also be changed simultaneously by the SLMP command
gateway
(IPAdressSet).
setting 4
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
PN23
Set the time interval between the transmissions of the alive check message (Keep
Alive ACK) for TCP communication.
*KAA
If no response to the alive check message is received, the connection is forcibly
KeepAlive
closed after the time (setting value × 8 times) has elapsed. In the initial setting, the
time
connection is closed after 8 hours (3600 [s] × 8 times = 28800 [s]) have elapsed.
This parameter can be used only when Modbus/TCP is set.
Setting range: 1 to 7200
PN24
Set the 1st octet of the IP address of the network device allowed to be connected in
decimal.
*IPAF1
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
IP address
disabled.
filter 1
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
PN25
Set the 2nd octet of the IP address of the network device allowed to be connected in
decimal.
*IPAF2
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
IP address
disabled.
filter 2
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
PN26
Set the 3rd octet of the IP address of the network device allowed to be connected in
decimal.
*IPAF3
When [Pr. PN24] to [Pr. PN27] are all set to "0", the IP address filtering function is
IP address
disabled.
filter 3
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
Function
5 - 10
Initial
value
[unit]
192
168
3
1
3600
[s]
0
0
0