7. OBJECT DICTIONARY

7.5.15 Setup S/W graph trigger (2D99h)

Sub
Index
Index
2D99h
0
Setup S/W graph trigger
This object can be used on the servo amplifiers with software version A4 or later.
The graph trigger of the setup software can be set.
The broadcast communication of Modbus RTU enables the multi axis waveform data to be measured with
MR Configurator2.
Setting value
0
1
(1) Usage
To measure and display the multi axis graph, follow the procedure below.
(a) Setting the measuring conditions
Set the trigger conditions and each monitoring data type of the measurement target. Apply the same
setting to all the target axes. Setting values are not specified except for 1) to 3).
1) Set "Number of collection Div" to a value equal to or less than 10 Div.
2) Set "*EXT*" for "Data".
3) Set "Single" for "Mode".
Name
Description
Setup software graph trigger off
Setup software graph trigger on
1)
2)
3)
7 - 49
Data
No. of Points/
Access
Type
No. of Registers
U8
rw
1
Continuous read/
continuous write
Impossible