7. OBJECT DICTIONARY
(5) Bit definition of status DO 5
Bit
Symbol
0
The value at reading is undefined.
1
2
3
4
Rough match
When a command remaining distance is lower than the rough match output range set with [Pr. PT12],
5
S_CPO
S_CPO turns on.
This bit can be used on the servo amplifiers with software version A4 or later.
Travel completion
When the droop pulses are within the in-position output range set with [Pr. PA10] and the command
remaining distance is "0", S_MEND turns on.
6
S_MEND
S_MEND turns on with servo-on.
This bit can be used on the servo amplifiers with software version A4 or later.
Home position return completion
When a home position return is completed properly, the S_ZP turns on.
In the incremental system, this signal turns off with one of the following conditions:
1) The servo motor enters the servo-off status.
2) EM2 is off.
3) RES (Reset) is on.
4) An alarm occurs.
5) LSP (Forward rotation stroke end) or LSN (Reverse rotation stroke end) is off.
6) Home position return is not being executed.
7) Software limit is being detected.
8) Home position return is in progress.
The S_ZP output status is the same as the S_RD even when the home position return is completed only
7
S_ZP
once in the absolute position detection system. However, it is off with one of the above conditions 1) to 8)
or the following conditions 9) to 14).
9) The home position return is not performed after [AL. 25 Absolute position erased] or [AL. E3 Absolute
10) The home position return is not performed after the electronic gear ([Pr. PA06 Electric gear numerator]
11) The home position return is not performed after the setting of [Pr. PA03 Absolute position detection
12) [Pr. PA14 Rotation direction selection/travel direction selection] was changed.
13) [Pr. PA01 Operation mode] was changed
14) [Pr. PT08 Home position return position data], [Pr. PT58 Number of stations per rotation (extension
This bit can be used on the servo amplifiers with software version A4 or later.
During a temporary stop
This is available only in the point table mode. When a deceleration begins for a stop, the S_PUS is turned
8
S_PUS
on by the TSTP (Temporary stop/restart). When TSTP is enabled again and an operation is restarted,
S_PUS turns off.
This bit can be used on the servo amplifiers with software version A4 or later.
9
The value at reading is undefined.
10
11
12
13
14
15
position counter warning] occurred.
and [Pr. PA07 Electric gear denominator]) was changed.
system selection] was changed from "Disabled" to "Enabled".
parameter)], or [Pr. PT28 Number of stations per rotation] was changed
Description
7 - 44