Default settings for commissioning
To configure the communication of the inverter via AS-i, the following possibilities are
available for commissioning the inverter:
● Default setting 30 - Single Slave mode, standard addressing
Single Slave mode with specification of a fixed frequency via the control
● Default setting 31 - Dual Slave mode with fixed setpoints
Dual Slave mode with specification of a fixed frequency via the control
● Default setting 32 - Single Slave mode, modified addressing:
Single Slave mode with "ON clockwise / OFF1", "ON counter-clockwise / OFF1", speed
setpoint via CDS0 or CDS1
● Default setting 34 - Dual Slave mode with "ON/OFF1", "OFF2"
Dual Slave mode with "ON/OFF1", "OFF2", speed setpoint via control
Details about the default settings are provided in the operating instructions of your inverter.
Connection
The following table shows the AS-i plug assignment. Further connection information is
contained in the AS-Interface system manual.
(https://support.industry.siemens.com/cs/gb/en/view/1171856)
Table 4- 8
X03 AS-i (M12)
4.4.4.1

Setting the address

As factory setting, all AS-i slaves have address 0. Slaves with address 0 are not included in
the communication.
The addresses must be unique, although they can be mixed as required.
You have the following options when making the address assignment:
● Automatic addressing via the AS-i master
● Addressing via the addressing device
● Addressing via parameters
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
Inverter factory setting (Page 108)
AS-i System Interface Manual
Pin assignment
Pin
1
2
3
4
5
4.4 Connecting the inverter to the fieldbus
Function
Description
AS-i +
AS-i plus signal
0 V
Reference potential for terminal 4
AS-i -
AS-i minus signal
24 V
24 V auxiliary voltage
Not assigned