3.2

SINAMICS G110M converter

Overview
The SINAMICS G110M system consists of the following components:
Terminal Hous-
ing (TH)
Power Module
(PM)
Three-phase
motor
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
The TH acts as the connection between the G110M and
the motor. The TH replaces the normal motor terminal
box.
The TH contains the following components:
Communications and Power
Interface (CPI)
Control Module (CM)
The PM provides the power to the converter and through
the DC link provides power to the low voltage circuits in
the CM and the PM.
The SINAMICS G110M is designed for mounting on the
SIMOGEAR geered motors. It is compatible with motors
of frame sizes 71 to 112.
3.2 SINAMICS G110M converter
The CPI provides all the
input and outputs con-
nections for the con-
verter. In addition it
allows for the provision
of an optional external
24 V power supply.
The CM interfaces with
the CPI and the con-
verter to provide all the
command and control
functions of the con-
verter.
Description
29