Siemens Sinamics G110M Operating Instructions Manual page 268

Sinamics series distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Advanced commissioning
6.22 Motor protection by calculating the temperature
Parameter Description
p0344
p0604
p0605
p0612
p0627
p0625
r0632
p0640
Further information is provided in the function charts 8016 and 8017 of the List Manual.
268
12:
Alarm A07012 and fault F07011
The inverter does not reduce the current limit.
After switching off the supply voltage, the inverter saves the most-recently calcu-
lated difference to the ambient air temperature. After switching the supply voltage
on again, the thermal motor model starts with 90 % of the previously saved differ-
ence temperature.
Motor weight (for thermal motor type) (factory setting: 0.0 kg)
Mot_temp_mod 2/KTY alarm threshold (factory setting: 130.0°
C)
Motor temperature > p0604 ⇒ fault F07011.
Mot_temp_mod 1/2 threshold (factory setting: 145.0° C)
Motor temperature > p0605 ⇒ alarm A07012.
Mot_temp_mod activation
.01
1 signal: Activate motor temperature model 2 for induc-
tion motors
.09
1 signal: Activate motor temperature model 2 expan-
sions
The inverter sets bit 09 = 1 after commissioning. If you
load the parameter settings for firmware version ≤ V4.6
into the inverter, bit 09 = 0 remains.
Motor overtemperature, stator winding (factory setting: 80 K)
Motor ambient temperature during commissioning (factory setting: 20° C)
Specification of the motor ambient temperature in °C at the instant of the motor data
identification.
Mot_temp_mod stator winding temperature [°C]
Current limit [A]
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
After selecting an induc-
tion motor (p0300) or a
listed induction motor
(p0301) during the com-
missioning, the inverter
sets the parameters to
values appropriate for
the motor.
The parameters are
write-protected for listed
motors (p0301 ≥ 0).

Hide quick links: