Alarms, faults and system messages
8.5 Alarms, alarm buffer, and alarm history
Parameter
r2123
r2124
r2125
r2145
r2132
r2134
r2146
Extended settings for alarms
Parameter
You can change up to 20 different alarms into a fault or suppress alarms:
p2118[0 ... 19
]
p2119[0 ... 19
]
You will find details in function diagram 8075 and in the parameter description of the List
Manual.
310
Description
Alarm time received in milliseconds
Displays the time in milliseconds when the alarm occurred
Alarm value
Displays additional information about the alarm
Alarm time removed in milliseconds
Displays the time in milliseconds when the alarm was removed
Alarm time received in days
Displays the time in days when the alarm occurred
Actual alarm code
Displays the code of the alarm that last occurred
Alarm value for float values
Displays additional information about the alarm that occurred for float values
Alarm time removed in days
Displays the time in days when the alarm was removed
Description
Setting the message number for the message type
Selection of the alarms for which the message type should be changed
Setting the message type
Setting the message type for the selected alarm
1: Fault
2: Alarm
3: No message
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH