Activating And Deactivating Know-How Protection - Siemens Sinamics G110M Operating Instructions Manual

Sinamics series distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Data backup and series commissioning
7.5 Know-how protection
Parameter
Parameter
p7763
p7764
7.5.2

Activating and deactivating know-how protection

Activating know-how protection
Preconditions
● The inverter has now been commissioned.
● You have generated the exception list for know-how protection.
● To guarantee know-how protection, you must ensure that the project does not remain at
the end user as a file.
Procedure with STARTER
Proceed as follows to activate know-how protection:
1. Go online with STARTER.
If you have generated a project offline on your computer, you must load the project into
the inverter and go online.
2. Select the required inverter in the project.
3. In the shortcut menu, select "Know-how protection drive unit/activating ....".
298
Description
KHP OEM exception list number of indices for p7764 (factory setting 1)
KHP OEM exception list (factory setting [0] 7766, [1 ...499 ] 0)
p7766 is the password for know-how protection
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH

Hide quick links: