Table A- 2
New functions and function changes in firmware 4.7 SP6
Function
1
Support for the Power Module PM240-2, FSF frame sizes
Support of PM240P-2 Power Modules frame sizes FSD ... FSF
Support of safety function Safe Torque Off (STO)via the terminals of the
PM240-2 Power Module, frame size FSF and PM240P-2 Power Module
FSD ... FSF
You can find additional information in the "Safety Integrated" function
manual.
Manuals for your converter (Page 372)
2
Support for Power Module PM330 JX frame size
3
Support for 1PC1 induction motors
4
The control of synchronous reluctance takes into account the inductance
of the output reactor.
5
Support of motor temperature sensor Pt1000
6
New p4621 parameter for disabling PTC short-circuit monitoring
7
Revision of the thermal motor model for protecting the motor against
damage due to overheating in the stator or rotor
8
Changing the quick commissioning in the "Standard Drive Control" appli-
cation class:
The motor data identification is no longer permanently set to p1900 = 12;
instead, users select the appropriate motor data identification.
Factory setting: p1900 = 2.
9
The free function blocks are also available in the SINAMICS G120C.
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH