2 Troubleshooting Procedures
Procedure 2
Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.
Start
Error code (8 bit)
"1"
"0"
Interval between data bits
The error code begins with the least significant digit.
Example:
Error code 11h (Error codes are given in hexadecimal format.)
Start
Check 1
Convert the DC IN icon blink pattern into the hexadecimal error code and compare
it to the tables below. Then go to Check 2.
2-8
2.3 Power Supply Troubleshooting
Off for 2 seconds
On for one second
On for half second
Off for half second