4 Replacement Procedures
6. Place the LCD panel (G) on the backlight unit (F).
CAUTION: Make sure there is no dust between the LCD panel and backlight unit. If any
dust is found, remove it with crepe tape or others, which has no remaining of
paste.
Make sure the LCD panel is installed in the
guide rib surely.
Figure 4-63 Replacing Sharp fluorescent lamp (XGA) (17)
4-84
4.25 Fluorescent Lamp
Guide rib
Guide rib
QOSMIO E10 Maintenance Manual (960-492)
Guide rib
Guide rib