Auxiliary Area Allocations by Address

Read-only Area (Set by System)
Address
Name
Words
Bits
A0
---
10-ms Incre-
menting Free
Running
Timer
A1
---
100-ms Incre-
menting Free
Running
Timer
A90 to
All
User Program
A93
Date
Appendix D
Function
This word contains the system timer
used after the power is turned ON.
A value of 0000 hex is set when the
power is turned ON and this value is
automatically incremented by 1 every
10 ms. The value returns to 0000 hex
after reaching FFFF hex
(655,350 ms), and then continues to
be automatically incremented by 1
every 10 ms.
Note: The timer will continue to be
incremented when the operat-
ing mode is switched to RUN
mode.
Example: The interval can be
counted between processing A and
processing B without requiring timer
instructions. This is achieved by
calculating the difference between
the value in A0 for processing A and
the value in A0 for processing B. The
interval is counted in 10 ms units.
This word contains the system timer
used after the power is turned ON.
A value of 0000 hex is set when the
power is turned ON and this value is
automatically incremented by 1 every
100 ms. The value returns to 0000
hex after reaching FFFF hex
(6,553,500 ms), and then continues
to be automatically incremented by 1
every 100 ms.
Note: The timer will continue to be
incremented when the operat-
ing mode is switched to RUN
mode.
Example: The interval can be
counted between processing A and
processing B without requiring timer
instructions. This is achieved by
calculating the difference between
the value in A0 for processing A and
the value in A0 for processing B. The
interval is counted in 100 ms units.
These words contain in BCD the
date and time that the user program
was last overwritten.
A90.00 to A90.07:
Seconds (00 to 59)
A90.08 to A90.15:
Minutes (00 to 59)
A91.00 to A91.07: Hour (00 to 23)
A91.08 to A91.15:
Day of month (01 to 31)
A92.00 to A92.07: Month (01 to 12)
A92.08 to A92.15: Year (00 to 99)
A93.00 to A93.07: Day of the week
(00: Sunday, 01: Monday, 02: Tues-
day, 03: Wednesday, 04: Thursday,
05: Friday, 06: Saturday)
Settings
Status
Status
after
at star-
mode
change
---
Retained Cleared
---
Retained Cleared
---
Retained Retained ---
Write
Related
timing
flags, set-
tup
tings
Every
---
10 ms after
power is
turned ON
Every
---
100 ms
after power
is turned
ON
---
663