Omron CP1H-X40D Operation Manual page 734

Cpu unit sysmac cp series
Hide thumbs Also See for CP1H-X40D:
Table of Contents

Advertisement

Auxiliary Area Allocations by Address
Addresses
Name
Word
Bits
A595
All
IR00 Output
and
for Back-
A596
ground Exe-
cution
A597
All
DR00 Out-
put for Back-
ground
Execution
A598
A598.00 FPD Teach-
ing Bit
A598.01 Equals Flag
for Back-
ground Exe-
cution
A600 to
All
Macro Area
A603
Input Words
A604 to
All
Macro Area
A607
Output
Words
A619
A619.01 Serial Port 1
Settings
Changing
Flag
A619.02 Serial Port 2
Settings
Changing
Flag
A620
A620.01 Communica-
tions Unit 0,
Port 1 Set-
tings Chang-
ing Flag
A620.02 Communica-
tions Unit 0,
Port 2 Set-
tings Chang-
ing Flag
A620.03 Communica-
tions Unit 0,
Port 3 Set-
tings Chang-
ing Flag
A620.04 Communica-
tions Unit 0,
Port 4 Set-
tings Chang-
ing Flag
700
Function
When an index register is specified as
the output for an instruction processed
in the background, A595 and A596
receive the output instead of IR00.
When a data register is specified as the
output for an instruction processed in
the background, A597 receives the out-
put instead of DR00.
Turn this bit ON to set the monitoring
time automatically with the teaching
function.
While A598.00 is ON, FPD(269) mea-
sures how long it takes for the diagnos-
tic output to go ON after the execution
condition goes ON. If the measured
time exceeds the monitoring time, the
measured time is multiplied by 1.5 and
that value is stored as the new monitor-
ing time.
(The teaching function can be used only
when a word address has been speci-
fied for the monitoring time operand.)
Turns ON if matching data is found for
an SRCH(181) instruction executed in
the background.
Before the subroutine specified in
MCRO(099) is executed, the source
words for the subroutine are transferred
to A600 through A603 (input parameter
words).
After the subroutine specified in
MCRO(099) has been executed, the
results of the subroutine are transferred
from A604 through A607 to the speci-
fied destination words (output parame-
ter words).
ON while the serial port 1's communica-
tions settings are being changed. This
flag will be turned ON when STUP(237)
is executed and it will be turned OFF
after the settings have been changed.
ON while the serial port 2's communica-
tions settings are being changed. This
flag will be turned ON when STUP(237)
is executed and it will be turned OFF
after the settings have been changed.
The corresponding flag will be ON when
the settings for that port are being
changed.
The flag will be turned ON when
STUP(237) is executed and it will be
turned OFF by an event issued from the
Serial Communications Unit after the
settings have been changed.
It is also possible for the user to indicate
a change in serial port settings by turn-
ing these flags ON.
Settings
Status
Status
after
at star-
mode
change
0000 0000 to
Cleared
Cleared
FFFF FFFF
hex
(A596 contains
the leftmost
digits.)
0000 to FFFF
Cleared
Cleared
hex
ON: Teach
Cleared
Cleared
monitoring time
OFF: Teaching
function OFF
ON: Search
Cleared
Cleared
data found in
table
OFF: Search
data not found
Input data:
Cleared
Cleared
4 words
Output data:
Cleared
Cleared
4 words
ON: Changing
Retained Cleared
OFF: Not
changing
ON: Changing
Retained Cleared
OFF: Not
changing
ON: Changing
Retained Cleared
OFF: Not
changing
ON: Changing
Retained Cleared
OFF: Not
changing
ON: Changing
Retained Cleared
OFF: Not
changing
ON: Changing
Retained Cleared
OFF: Not
changing
Appendix D
Write
Related
timing
Flags,
tup
Settings
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp1h-xa40dCp1h-y20dt-dCp1h

Table of Contents