Plc Setup; High-Speed Counter Terminal Allocation - Omron CP1H-X40D Operation Manual

Cpu unit sysmac cp series
Hide thumbs Also See for CP1H-X40D:
Table of Contents

Advertisement

High-speed Counters
5-2-4

PLC Setup

Settings in the Built-
in Input Tab
5-2-5

High-speed Counter Terminal Allocation

218
The settings for high-speed counters 0 to 3 are located in the Built-in Input
Tab of the CX-Programmer's PLC Settings Window.
Item
Use high speed counter 0 to 3 Use counter
Counting mode
Circular Max. Count
(max. ring count)
Reset method
Input Setting
The following diagrams show the input terminals that can be used for high-
speed counters in each CPU Unit.
Setting
Linear mode
Circular mode (ring mode)
0 to 4,294,967,295 (0 to FFFF FFFF hex)
Phase Z and software reset
Software reset
Phase Z and software reset (continue comparing)
Software reset (continue comparing)
Differential phase inputs (4x)
Pulse + direction inputs
Up/Down inputs
Increment pulse input
Section 5-2