Ethernet Option Board Function Guide - Omron CP1H-X40D Operation Manual

Cpu unit sysmac cp series
Hide thumbs Also See for CP1H-X40D:
Table of Contents

Advertisement

Ethernet Option Board Function Guide

9-1
Ethernet Option Board Function Guide
9-1-1
Overall system configuration example
Connecting through multiple segments, such as over the Internet:
Use FINS/TCP.
FINS
IP router
Firewall
Router
Ethernet Option Board
Note
1. Please use CX-Programmer version 8.1 or higher (CX-ONE version 3.1 or higher).
2. Please use CX-Integrator version 2.33 or higher (CX-ONE version 3.1 or higher) to make the
routing table. Except making the routing table for CP1W-CIF41, other functions, such as trans-
ferring the parameters and network structure, are not supported by CX-Integrator.
3. Use the Web browser to set the CP1W-CIF41.
4. NS-series HMI version 8.2 or higher can use CP1W-CIF41 through Ethernet.
5. Expect for CX-Programmer and CX-Integrator (only set FINS routing table function), other tools
do not support CP1W-CIF41.
546
Ethernet Option Board provides receiving commands by OMRON standard
protocol FINS for CP1L and CP1H programmable controllers. The Ethernet
Network Interface allows you to easily connect CP1L and CP1H Programma-
ble Controllers onto new or existing Ethernet network and upload/download
programs, communicate between controllers (do not support real-time scan-
ning I/O on Ethernet Option Board).
Internet
Intranet
(Server room)
(Office floor)
CX-Programmer
Ethernet
Router
(Production line)
Ethernet
PLC
Ethernet Option Board
FINS
Ethernet
NS-series PT
Connecting within the same segment:
Use FINS/UDP.
FINS
FINS
Wireless
PLC
FINS
Section 9-1
Using media with unreliable
connections, such as wireless
LAN: Use FINS/TCP.