Pulse Outputs
312
■ DM Area Settings
Starting Frequency
Setting details
X-axis starting frequency
Y-axis starting frequency
PLS2(887) Settings to Move from Origin to Position A
Setting details
X axis
Acceleration rate: 2,000 Hz/4 ms
Deceleration rate: 2,000 Hz/4 ms
Target frequency: 100,000 Hz
Number of output pulses: 5,000 pulses
Y axis
Acceleration rate: 2,000 Hz/4 ms
Deceleration rate: 2,000 Hz/4 ms
Target frequency: 100,000 Hz
Number of output pulses: 5,000 pulses
PLS2(887) Settings to Move from Position A to Position B
Setting details
X axis
Acceleration rate: 2,000 Hz/4 ms
Deceleration rate: 2,000 Hz/4 ms
Target frequency: 100,000 Hz
Number of output pulses: 25,000 pulses
Section 5-3
Address
Data
D0
#0000
D2
#0000
Address
Data
D10
#07D0
D11
#07D0
D12
#86A0
D13
#0001
D14
#1388
D15
#0000
D20
#07D0
D21
#07D0
D22
#86A0
D23
#0001
D24
#1388
D25
#0000
Address
Data
D30
#07D0
D31
#07D0
D32
#86A0
D33
#0001
D34
#61A8
D35
#0000