Auxiliary Area Allocations by Function
Name
Equals Flag for Background
Execution
ER/AER Flag for Back-
ground Execution
Function Block Information
Function Block Memory Information
Name
FB Program Data Flag
OMRON FB Library Information
Name
FB Communications Instruc-
tion Response Required
FB Communications Instruc-
tion Port No.
FB Communications Instruc-
tion Retries
FB Communications Instruc-
tion Response Monitoring
Time
FB DeviceNet Communica-
tions Instruction Response
Monitoring Time
Note
These Auxiliary Area bits/words are not to be written by the user. The number of resends and response monitoring time must be
set by the user in the FB communications instructions settings in the PLC Setup, particularly when using function blocks from the
OMRON FB Library to execute FINS messages or DeviceNet explicit messages communications. The values set in the Settings for
OMRON FB Library in the PLC Setup will be automatically stored in the related Auxiliary Area words A580 to A582 and used by
the function blocks from the OMRON FB Library.
Ethernet Option Board Flag
System Settings Reset
Name
Ethernet Option Board
Reset Flag
Unit Restart
Name
Ethernet Option Board
Restart Flag
662
Address
A598.01
Turns ON if matching data is found for an SRCH(181)
instruction executed in the background.
A395.10
ON when an instruction processing error or an illegal
area access error occurs during background processing.
OFF (0) when background processing starts or power is
turned ON.
Address
A345.00
Turns ON if the FB program memory contains FB pro-
gram data.
OFF: No data
ON: Data present
Address
A580.15
0: Not required
1: Required
A580.08 to
0 to 7 hex: Communications port No. 0 to 7
A580.11
F hex: Automatic allocation
A580.00 to
Automatically stores the number of retries in the FB com-
A580.03
munications instruction settings specified in the PLC
Setup.
A581
Automatically stores the FB communications instruction
response monitoring time set in the PLC Setup.
0001 to FFFF hex (Unit: 0.1 s; Range: 0.1 to 6553.5)
0000 hex: 2 s
A582
Automatically stores the FB DeviceNet communications
instruction response monitoring time set in the PLC
Setup.
0001 to FFFF hex (Unit: 0.1 s; Range: 0.1 to 6553.5)
0000 hex: 2 s
Address
A525.00 to
If the flag turns ON, the Ethernet Option Board mounted
A525.01
on the corresponding option board slot will reset the sys-
tem settings to default values.
Address
A525.08 to
If the flag turns ON, the Ethernet Option Board mounted
A525.09
on the corresponding option board slot will be restarted.
Description
Description
Description
Description
Description
Appendix C
Access
Updated
Read-only
Read-only
Access
Updated
Read-only
Access
Updated
Read-only
Read-only
Read-only
Read-only
Read-only
Access
Updated
Read/write
Access
Updated
Read/write