Check For Dust Stripes / Tph Cleaning Procedure - AGFA DRYSTAR 5302 Technical Documentation Manual

Hide thumbs Also See for DRYSTAR 5302:
Table of Contents

Advertisement

DD+DIS150
.05E
Select densitometer:
Square Measured density Target density Density diff. Check
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
When entering the measured density values the decimal point appears in a different spot, e.g. measured value = 0.23, value to enter = 23.0
Density
Lower limit
0
30
45
60
75
90
105
120
135
150
165
180
195
210
225
240
255
270
285
300
315
(4) After the measured values are filled in, the density reproduction is calculated
automatically.
(5) At the right hand side of the table is shown, whether the Density Reproduction is
ok or not. In case it is not ok you are requested to carry out a CDM calibration.
3.2

Check for Dust Stripes / TPH Cleaning Procedure

Whenever dust stripes seem to be present.
To be done
During troubleshooting procedure
(1)
Check the films for dust stripes as described in the flowchart of
Figure 20.
The controlled version of this document resides on MedNet. Any printed copy of this document is uncontrolled.
Edition 1, Revision 1
05-2009
X-rite 341
4
23
23
0
50
52,2
-2,2
78
81,4
-3,4
105
110,6
-5,6
135
139,8
-4,8
162
169
-7
193
198,2
-5,2
221
227,4
-6,4
250
256,6
-6,6
280
285,8
-5,8
308
315
-7
Upper limit
0
0
-5
5
-7
7
-8
8
-9
9
-10
10
-11
11
-12
12
-12
12
-13
13
-13
13
-14
14
-14
14
-14
14
-15
15
-15
15
-15
15
-16
16
-16
16
-16
16
-16
16
DOCUMENT CONTROL NOTE:
DRYSTAR 5302
Type 5366/100
Adjustments and Calibrations
Dmax = 315
0
0
0
0
Density Reproduction =
0
No CDM calibration needed for DT2B film
0
0
0
0
0
0
Density difference LinCheck image DT2B film in DS5302
20
15
X-rite 310
10
X-rite 331
X-rite 341
5
X-rite 301
Mac Beth TR924
0
Gretag D200-2
-5
-10
-15
-20
0
50
100
150
200
Target Density
Figure 19
Repair and Service
OK
Lower limit
Upper limit
Density difference
250
300
350
Chapter 3.6 / 32
Agfa Company Confidential