12.3.6 Elevator Motor Assembly
Removal
1. Open the feeder drawer and remove all paper.
2. Disconnect the AC Power Cord from the High Capacity Feeder.
3. Remove the four screws that secure the Rear Access Cover. Remove the access cover.
4. Disconnect J2 from the Feeder Controller PWB (Figure 12.3.6.1).
5. Remove the four screws that secure the Elevator Motor Assembly (Figure 12.3.6.1).
6. Remove the assembly.
Replacement
1. Perform the removal steps in reverse order.
High Capacity Feeder Option
Figure 12.3.6.1 Elevator Motor Assembly
6/98
www.printcopy.info
12-16
J6
J5
4
J2
J4
J3
J1
J8
J7
J9
5
rep_06
Xerox DocuPrint N17 Service Manual