12.3.5 Controller PWB

Removal
1. Disconnect the AC Power Cord from the High Capacity Feeder.
2. Remove the four screws that secure the Rear Access Cover. Remove the access cover.
3. Disconnect 8 connectors (J1, J2, J3, J4, J5, J7, J8, and J9) from the Feeder Controller PWB (Figure
12.3.5.1).
4. Remove the screw that secures the lower corner of the Controller PWB and gently lift the PWB off of
the three support posts on the chassis (Figure 12.3.5.1).
Replacement
1. Perform the removal steps in reverse order.
Xerox DocuPrint N17 Service Manual
Figure 12.3.5.1 Controller PWB
6/98
www.printcopy.info
12-15
3
J2
J1
4
J7
High Capacity Feeder Option
J6
J5
J4
J3
J8
J9