Oracle Netra SPARC T4-1B Service Manual page 97

Server module
Table of Contents

Advertisement

c. Switch to the host console to view POST output.
Watch the POST output for possible fault messages. The following output
indicates that POST did not detect any faults:
-> start /HOST/console
.
.
.
0:7:2>INFO:
0:7:2>
POST Passed all devices.
0:7:2>POST:
Return to VBSC.
0:7:2>Master set ACK for vbsc runpost command and spin...
Note – The server module might boot automatically at this point. If so, go directly to
Step
e. If it remains at the ok prompt go to
d. If the server module remains at the ok prompt, type boot.
e. Return the virtual keyswitch to Normal mode.
-> set /SYS keyswitch_state=Normal
Set 'ketswitch_state' to 'Normal'
f. Switch to the host console and type the Oracle Solaris OS fmadm faulty
command.
# fmadm faulty
If any faults are reported, see the diagnostics instructions in
Troubleshooting Overview" on page
5. Switch to the Oracle ILOM command shell.
Step
d.
12.
Servicing Memory
"Oracle ILOM
87

Advertisement

Table of Contents
loading

Table of Contents