6. Type the show faulty command.
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
If the show faulty command reports a fault with a UUID go to
faulty does not report a fault with a UUID, you have completed the verification
process.
7. Switch to the host console and type the fmadm repair command with the
UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show
faulty command.
# fmadm repair 3aa7c854-9667-e176-efe5-e487e520
Related Information
"Remove a DIMM" on page 80
"Install a DIMM" on page 81
"DIMM Configuration" on page 77
88
Netra SPARC T4-1B Server Module Service Manual • June 2012
| Property
| fru
| timestamp
| sunw-msg-id
|
| uuid
|
| timestamp
|
| Value
| /SYS/MB/CMP0/BOB0/CH1/D0
| Dec 14 22:43:59
| SUN4V-8000-DX
|
| 3aa7c854-9667-e176-efe5-e487e520
| 7a8a
| Dec 14 22:43:59
|
Step
7. If show