c. Select the Knowledge tab.
d. Search for that message ID in the Knowledge Base.
e. Follow the suggested actions to repair the fault.
Related Information
"Clear PSH-Detected Faults" on page 44
■
▼ Clear PSH-Detected Faults
When PSH detects faults, the faults are logged and displayed on the console. In most
cases, after the fault is repaired, the server module detects the corrected state and
repairs the fault condition automatically. However, you should verify this repair. In
cases where the fault condition is not automatically cleared, you must clear the fault
manually.
1. After replacing a faulty FRU, power on the server module.
2. At the host prompt, determine if the replaced FRU still shows a faulty state.
# fmadm faulty
TIME
EVENT-ID
Aug 13 11:48:33 21a8b59e-89ff-692a-c4bc-f4c5cccca8c8
Platform
: sun4v
Product_sn
:
Fault class : fault.cpu.generic-sparc.strand
Affects
: cpu:///cpuid=**/serial=*********************
FRU
: "/SYS/MB"
(hc://:product-id=*****:product-sn=**********:server-id=***-******-*****:
chassis-id=********:**************-**********:serial=******:revision=05/
chassis=0/motherboard=0)
Description : The number of correctable errors associated with this strand has
exceeded acceptable levels.
Response
: The fault manager will attempt to remove the affected strand
from service.
Impact
: System performance may be affected.
44
Netra SPARC T4-1B Server Module Service Manual • June 2012
Chassis_id
faulted and taken out of service
faulty
:
MSG-ID
SEVERITY
SUN4V-8002-6E
Major