Use the[
desred new U.R. pont and then press the [ENTER] key. At such tme, the X= and Y= coordnate values respectvely
represent the current pen carrage poston as X- and Y-axs dsplacements from the orgnal orgn.
To select the default U.R. pont, press the [F3] key (DEFAULT). You do not need to press the [ENTER] key f the
default U.R. pont was selected.
(6) Press the [PAUSE] key to cancel PAUSE mode.
This setting returns to its default status when the power is turned off.
After this setting has been made, the origin moves to the same position as the lower left position
The L.L. and U.R. positions cannot be specified outside of the actual area of the loaded cutting medium.
The effective cutting area can only be set by specifying the lower left and upper right points. If the effective cutting
area is incorrectly specified (by, for example, specifying the upper left or lower right point or specifying lower left
and upper right points that are less than 5 mm apart in either the X or the Y axis, the message below appears for
several seconds. In this case, set the effective cutting area over again.
FORCE
ILLEGAL PLOT AREA
SPEED
When the ROTATE or MIRROR mode is selected or cancelled after specifying new L.L. and U.R. positions, your L.L.
and U.R. settings are initialized to their default positions (the lower left and upper right corners of the maximum
effective cutting area).
] keys to move the pen carrage (the tp of the tool selected by the current settng) to the
OFFSET
QUALITY
Chapter 5 FUNCTION SETTINGS AND OPERATIONS