4.9 Setting the Registration Mark Detection Speed
Ths functon sets the speed of the pen carrage at the tme when regstraton mark lnes are detected.
Change the speed settng f regstraton marks cannot be detected due to the type of meda used or the
thckness of the regstraton mark lnes.
(1) Press the [PAUSE] key to select PAUSE mode.
(2) Press the [NEXT] key repeatedly untl the followng menu s dsplayed.
FORCE
MARK
BUFFER CLR.
SPEED
(3) Press the [F1] key (MARK) to dsplay the regstraton mark functons selecton menu.
FORCE
MODE
TYPE
OTHER SETUPS
SPEED
(4) Press the [F4] key (OTHER SETUPS) to dsplay the menu shown below.
FORCE
SIZE
ORG OFT
SPEED
(5) Press the [F4] key (SENS OPT) to dsplay the menu shown below.
FORCE
LEVEL
SENS SPD SENS STEP
SPEED
(6) Press the [F2] key (SENS SPD) to dsplay the menu shown below.
FORCE
SENSING SPEED
SPEED =
SPEED
] or [
Use the[
Setting range: 1 to 30 (cm/s) [Default value: 5]
Settng a slower speed (a smaller value) enables regstraton marks to be detected more easly.
(7) Press the [PAUSE] key to cancel PAUSE mode.
OFFSET
TOOL U/D
VIEW
QUALITY
OFFSET
DIST ADJ
QUALITY
OFFSET
ADJ. SENS
SENS OPT
QUALITY
OFFSET
QUALITY
OFFSET
5 cm/s
QUALITY
] key to change the numerc value, and then press the [ENTER] key to confirm your selection.
Chapter 4 REGISTRATION MARK SETTINGS AND DETECTION
4-17