Set Up Stereo/3D Configuration - RED epic Operation Manual

Hide thumbs Also See for epic:
Table of Contents

Advertisement

R E D D S M C O P E R AT I O N G U I D E : E P I C / S C A R L E T

SET UP STEREO/3D CONFIGURATION

This section describes basic procedures for connecting two (2) DSMC BRAINs in a Master/Slave configuration
for 3D operation.
NOTE: When providing the signals to a Stereo Image Processor (SiP) for verifying 3D alignment, set the HD-SDI
monitor output on both cameras to have the same overlay configuration.
NOTE: For genlock to function correctly, the cameras must be on the same firmware version, and must be using
the same project time base and recording frame rate.
To set up a Stereo/3D setup, follow the instructions below.
1. On both cameras, set the desired project time base and recording frame rate.
2. On both cameras, follow the instructions in
status.
The GEN and SYNC indicators in the Lower Status Row illuminate green.
3. Follow the instructions in
settings.
4. On both cameras, follow the instructions in
164
to prepare media and camera settings.
3D CONFIGURATION EXAMPLE
The diagram below is an example of how to set up a 3D configuration.
REQUIRED CABLES
 790-0163: Master/Slave Gig-E Cable
 790-0154: 3BNC-to-00 LEMO Sync Cable (required per camera)
COPYRIGHT © 2015 RED.COM, INC
"Sensor Sync" on page 161
"Set Up Master/Slave Operation" on page 162
"Set Reel Number, Camera ID, and Camera Position" on page
to achieve Sensor Sync genlock
to set Master and Slave camera
955-0020_V6.0, REV-J |