Automatically Notify Support: No User Response: No Action; Information Only - IBM System x3650 M5 Installation And Service Manual

Type 5462
Table of Contents

Advertisement

806f020d-041fffff • 806f0308-0a01ffff
806f020d-041fffff
Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 31)
Explanation: This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d041fffff or 0x806f020d041fffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk drive b. Cable from the system board to the backplane.
3.
Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive. b. Cable from the system board to the backplane. c. Hard disk drive backplane. (n = hard disk drive
number)
806f0223-2101ffff
Powering off system [ComputerSystemElementName] initiated by [WatchdogElementName].
(IPMI Watchdog)
Explanation: This message is for the use case when an implementation has detected a Poweroff by Watchdog has
occurred.
May also be shown as 806f02232101ffff or 0x806f02232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0372
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0308-0a01ffff
[PowerSupplyElementName] has lost input. (Power Supply 1)
Explanation: This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
May also be shown as 806f03080a01ffff or 0x806f03080a01ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0100
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Reconnect the power cords.
2.
Check power supply n LED.
494
System x3650 M5 Type 5462: Installation and Service Guide

Advertisement

Table of Contents
loading