IBM System x3650 M5 Installation And Service Manual page 962

Type 5462
Table of Contents

Advertisement

202-803-000 • 202-901-000
202-803-000
MemStr Test Aborted
Explanation: User pressed Ctrl-C.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
202-901-000
MemStr Test Failed
Explanation: Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Execute the standard DSA memory diagnostics to validate all memory.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Turn off the system and disconnect it from power.
4. Reseat the memory cards and DIMMs.
5. Reconnect the system to power and turn the system on.
6. Run the test again.
7. Execute the standard DSA memory diagnostics to validate all memory.
8. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
946
System x3650 M5 Type 5462: Installation and Service Guide

Advertisement

Table of Contents
loading