IBM System x3650 M5 Installation And Service Manual page 580

Type 5462
Table of Contents

Advertisement

806f052b-2101ffff • 806f0607-0301ffff
806f052b-2101ffff
Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName]. (IMM2 FW Failover)
Explanation: This message is for the use case when an implementation has detected an Invalid/Unsupported
Firmware/Software Version.
May also be shown as 806f052b2101ffff or 0x806f052b2101ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0446
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2.
Recover the server firmware from the backup page by restarting the server.
3.
Update the server firmware to the latest level (see Updating the firmware). Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster solution before you update the code.
4.
Remove components one at a time, restarting the server each time, to see if the problem goes away.
5.
If the problem remains, (trained service technician) replace the system board.
806f0607-0301ffff
An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.
(CPU 1)
Explanation: This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06070301ffff or 0x806f06070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0816
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Make sure that the installed microprocessors are compatible with each other (see Installing a microprocessor and
heat sink for information about microprocessor requirements).
2.
Update the server firmware to the latest level (see Updating the firmware).
3.
(Trained technician only) Replace the incompatible microprocessor.
564
System x3650 M5 Type 5462: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents