816f000d-0414ffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 20)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0414ffff or 0x816f000d0414ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Replace backplane.
816f000d-0415ffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 21)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0415ffff or 0x816f000d0415ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Replace backplane.
816f000d-0414ffff • 816f000d-0415ffff
Appendix A. Integrated management module II (IMM2) error messages
673