IBM System x3650 M5 Installation And Service Manual page 692

Type 5462
Table of Contents

Advertisement

816f000d-041affff • 816f000d-041bffff
816f000d-041affff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 26)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d041affff or 0x816f000d041affff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Replace backplane.
816f000d-041bffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 27)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d041bffff or 0x816f000d041bffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Replace backplane.
676