IBM System x3650 M5 Installation And Service Manual page 685

Type 5462
Table of Contents

Advertisement

816f000d-040cffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 12)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040cffff or 0x816f000d040cffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Replace backplane.
816f000d-040dffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 13)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040dffff or 0x816f000d040dffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Replace backplane.
816f000d-040cffff • 816f000d-040dffff
Appendix A. Integrated management module II (IMM2) error messages
669

Advertisement

Table of Contents
loading