IBM System x3650 M5 Installation And Service Manual page 420

Type 5462
Table of Contents

Advertisement

8007020d-2582ffff • 8007020f-2201ffff
8007020d-2582ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (RAID Vol
State)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020d2582ffff or 0x8007020d2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b.
Cable from the system board to the backplane
3.
Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive
number)
8007020f-2201ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (TXT ACM
Module)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2201ffff or 0x8007020f2201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
If enabling TXT is not required, disable TXT from the Setup Utility.
2.
If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
3.
If the problem remains, contact your service representative.