IBM System x3650 M5 Installation And Service Manual page 836

Type 5462
Table of Contents

Advertisement

I.18010 • I.2018003
I.18010
[I.18010]
Explanation: A processor stepping mismatch has been detected for one or more processor packages. Processors of
the same model have mismatched Stepping ID
Severity: Error
User response: Complete the following steps:
1.
Verify that matching processors are installed in the correct processor sockets. Correct any mismatch found.
2.
Check the IBM support site for an applicable service bulletin or firmware update that applies to this processor
error.
3.
(Trained technician only)Replace the system board
I.2018002
[I.2018002]
Explanation: The device found at Bus % Device % Function % could not be configured due to resource constraints.
The Vendor ID for the device is % and the Device ID is %. OUT_OF_RESOURCES (PCI Option ROM)
Severity: Info
User response: Complete the following steps:
1.
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat the
adapter and any attached cables.
2.
Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to
this error. NOTE: It may be necessary to disable unused option ROMs from UEFI F1 setup or ASU or using
adapter manufacturer utilities so that adapter firmware can be updated.
3.
Move the adapter to a different slot. If a slot is not available or error recurs, replace the adapter.
4.
If the adapter was moved to a different slot and the error did not recur, verify that this is not a system limitation.
Then replace the system board. Also, if this is not the initial installation and the error persists after adapter
replacement, replace the system board.
I.2018003
[I.2018003]
Explanation: A bad option ROM checksum was detected for the device found at Bus % Device % Function %. The
Vendor ID for the device is % and the Device ID is %. ROM CHECKSUM ERROR
Severity: Error
User response: Complete the following steps:
1.
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat the
adapter and any attached cables.
2.
Move the adapter to a different system slot, if available.
3.
Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to
this error. NOTE: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and
I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
4.
Replace the adapter.
820
System x3650 M5 Type 5462: Installation and Service Guide

Advertisement