800b050a-1e84ffff
Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted. (Fan
Zone 4)
Explanation: This message is for the use case when a Redundancy Set has transitioned to Non-
redundant:Insufficient Resources.
May also be shown as 800b050a1e84ffff or 0x800b050a1e84ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b050c-2581ffff
Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
(Backup Memory)
Explanation: This message is for the use case when a Redundancy Set has transitioned to Non-
redundant:Insufficient Resources.
May also be shown as 800b050c2581ffff or 0x800b050c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.