Replacing A Simple-Swap Hard Disk Drive - IBM System x3650 M5 Installation And Service Manual

Type 5462
Table of Contents

Advertisement

3.5-inch simple-swap
hard disk drive
Figure 82. 3.5-inch simple-swap hard disk drive removal
4. Reinstall the drive bay filler panel that you removed earlier, if needed.
5. If you are instructed to return the drive assembly, follow all packaging

Replacing a simple-swap hard disk drive

Use this information to install a simple-swap hard disk drive.
About this task
You must turn off the server before installing simple-swap drives in the server.
Before you install a simple-swap SATA hard disk drive, read the following
information. For a list of supported hard disk drives, see http://www.ibm.com/
systems/info/x86servers/serverproven/compat/us/.
v Locate the documentation that comes with the hard disk drive and follow those
v As a general consideration, do not mix standard 512-byte and advanced 4-KB
v Make sure that you have all the cables and other equipment that are specified in
v Select the bay in which you want to install the drive.
v Check the instructions that come with the drive to determine whether you have
v The simple-swap server models support up to sixteen 2.5-inch or eight 3.5-inch
v You can install one 2.5-inch simple-swap SATA hard disk drives in bay 0 in the
v The simple-swap server models are available only in non-RAID configurations.
v The electromagnetic interference (EMI) integrity and cooling of the server are
158
System x3650 M5 Type 5462: Installation and Service Guide
Release latch
instructions, and use any packaging materials for shipping that are supplied to
you.
instructions in addition to the instructions in this chapter.
format drives in the same RAID array because it may lead to potential
performance issues.
the documentation that comes with the drive.
to set any switches or jumpers on the drive. If you are installing a SATA device,
be sure to set the SATA ID for that device.
simple-swap SATA hard disk drives. Do not install hot-swap drives into a
simple-swap server model, it is not supported.
server. Do not install hot-swap drives into a simple-swap server model, it is not
supported.
protected by having all bays and PCI Express slots covered or occupied. When
you install a drive or a PCI Express adapter, save the EMC shield and filler
panel from the bay or PCI Express adapter slot cover in the event that you later
remove the device.