806f060d-040fffff • 806f060d-0410ffff
806f060d-040fffff
Array [ComputerSystemElementName] has failed. (Drive 15)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d040fffff or 0x806f060d040fffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a lit status LED.
806f060d-0410ffff
Array [ComputerSystemElementName] has failed. (Drive 16)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0410ffff or 0x806f060d0410ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a lit status LED.