IBM System x3650 M5 Installation And Service Manual page 571

Type 5462
Table of Contents

Advertisement

806f050d-040fffff
Array [ComputerSystemElementName] is in critical condition. (Drive 15)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d040fffff or 0x806f050d040fffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0410ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 16)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0410ffff or 0x806f050d0410ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-040fffff • 806f050d-0410ffff
Appendix A. Integrated management module II (IMM2) error messages
555

Advertisement

Table of Contents
loading

Table of Contents