IBM System x3650 M5 Installation And Service Manual page 852

Type 5462
Table of Contents

Advertisement

W.58007 • W.68002
W.58007
[W.58007]
Explanation: Invalid memory configuration (Unsupported DIMM Population) detected. Please verify memory
configuration is valid. Unsupported DIMM Population
Severity: Error
User response: Complete the following steps:
1.
Ensure that the DIMM connectors are populated according to the guidelines in the service information for this
product.
2.
Ensure all DIMM are enabled in the uEFI setup menu.
3.
If a DIMM connector error LED is lit, resolve the failure.
W.580A1
[W.580A1]
Explanation: Invalid memory configuration for Mirror Mode. Please correct memory configuration. Unsupported
DIMM Population for Mirror Mode
Severity: Error
User response: Complete the following steps:
1.
If a DIMM connector error LED is lit, resolve the failure.
2.
Make sure that the DIMM connectors are correctly populated for mirroring mode.
W.580A2
[W.580A2]
Explanation: Invalid memory configuration for Sparing Mode. Please correct memory configuration. Unsupported
DIMM Population for Spare Mode
Severity: Error
User response: Complete the following steps:
1.
If a DIMM connector error LED is lit, resolve the failure.
2.
Make sure that the DIMM connectors are correctly populated for sparing mode, according to the service
information for this product.
W.68002
[W.68002]
Explanation: A CMOS battery error has been detected CMOS Battery Fault
Severity: Error
User response: Complete the following steps:
1.
If the system was recently installed, moved, or serviced, make sure the battery is properly seated.
2.
Check the IBM support site for an applicable service bulletin or firmware update that applies to this error.
3.
Replace the CMOS battery.
4.
(Trained technician only)Replace the system board