IBM System x3650 M5 Installation And Service Manual page 573

Type 5462
Table of Contents

Advertisement

806f050d-0413ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 19)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0413ffff or 0x806f050d0413ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0414ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 20)
Explanation: This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0414ffff or 0x806f050d0414ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0413ffff • 806f050d-0414ffff
Appendix A. Integrated management module II (IMM2) error messages
557

Advertisement

Table of Contents
loading

Table of Contents