IBM System x3650 M5 Installation And Service Manual page 554

Type 5462
Table of Contents

Advertisement

806f050c-2007ffff • 806f050c-2008ffff
806f050c-2007ffff
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 7)
Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c2007ffff or 0x806f050c2007ffff
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the error still occurs on the same DIMM, replace the affected DIMM.
4.
If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any
foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
806f050c-2008ffff
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 8)
Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c2008ffff or 0x806f050c2008ffff
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0144
SNMP Trap ID: 43
Automatically notify Support: Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the error still occurs on the same DIMM, replace the affected DIMM.
4.
If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any
foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
538
System x3650 M5 Type 5462: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents