IBM System x3650 M5 Installation And Service Manual page 889

Type 5462
Table of Contents

Advertisement

408-801-000
MLNX:MLNX_DiagnosticTestIBPort Test Aborted
Explanation: Port Test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
408-900-000
MLNX:MLNX_DiagnosticTestEthernetPort Test Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under test in the active state.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
408-901-000
MLNX:MLNX_DiagnosticTestIBPort Test Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under test in the active state and a subnet manager running on the
fabric to which the port is attached.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
408-801-000 • 408-901-000
Appendix C. DSA diagnostic test results
873

Advertisement

Table of Contents
loading