S.3050007 • S.3060007
S.3050007
[S.3050007]
Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System
halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Update the UEFI image.
3.
Replace the system board.
S.3058004
[S.3058004]
Explanation: A Three Strike boot failure has occurred. The system has booted with default UEFI settings. POST
failure has occurred! System booted with default settings.
Severity: Error
User response: Complete the following steps:
1.
This event resets UEFI to the default settings for the next boot. If successful, the Setup Utility is displayed. The
original UEFI settings are still present.
2.
If you did not intentionally trigger the reboots, check logs for probable cause.
3.
Undo recent system changes (settings or devices added). If there were no recent system changes, remove all
options, and then remove the CMOS battery for 30 seconds to clear CMOS contents. Verify that the system boots.
Then, re-install the options one at a time to locate the problem.
4.
Check the IBM support site for an applicable service bulletin or firmware update that applies to this error.
5.
Update the UEFI firmware.
6.
Remove and re-install CMOS battery for 30 seconds to clear CMOS contents.
7.
(Trained service technician only) Replace the system board.
S.3060007
[S.3060007]
Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System
halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Update the UEFI image.
3.
Replace the system board.