IBM System x3650 M5 Installation And Service Manual page 982

Type 5462
Table of Contents

Advertisement

166-904-001 • 166-907-001
166-904-001
IMM I2C Test Failed
Explanation: IMM Indicates failure in PCA9557--I2C I/O Expander bus (BUS 3).
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
166-907-001
IMM I2C Test Failed
Explanation: IMM Indicates failure in PCA9545--4-Channel I2C Switch bus (BUS 6).
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
966
System x3650 M5 Type 5462: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents