VM² STATUS > VST SECTION
Mute (Shure)
Remotely mute the selected Shure wireless receiver.
Gain (Shure)
Remotely control the gain of the selected Shure wireless receiver.
Locate
Activate the Locate function on the selected AKG receiver.
Pressing this will cause the front panel display of the chosen receiver to flash, allowing it to be more easily identi-
fied among a rack of others.
Gain Select
Switch gain monitoring / control source
Choose RECV (wireless receiver) or DESK (input channel gain).
RF Strength (All Microphone types)
Radio Frequency signal strength.
Shows signal level in bargraph and dB readout.
Battery Level (All microhone types)
Remaining battery life as icon and numerical.
The remaining battery life numerical info in hours is only a guide, and depends on the type of cells used. The
battery icon gives an accurate picture of the current state. Note that the remaining time for Shure receivers is only
displayed if the mic has original Shure rechargeable batteries. If Alkaline batteries are used, the remaining time is
not displayed.
18.2.2: STATUS - VST
18.2.1: VM ² TOUCH SCREEN STATUS - VST