SoundCraft Vi5000 User Manual page 169

Table of Contents

Advertisement

®
Vi5000/7000 User Manual
16.9: SETTINGS MENU
MENU > SETTINGS
Set Meter In Point
Determine the metering point for the input channel level meters.
There are four choices for the input meter tap, from left to right: After the analogue mic gain (before digital trim
and filters); after the digital trim and filters (before the Gate/EQ/Dynamics); after the Gate/EQ/Dynamics (before
the fader); after the fader.
Graphic EQ Large/Small Mode
Choose between Large and Small Graphic EQ control modes.
Choose 'Large' 30-fader mode for fast access on multiple faders, at the expense of access to the input faders, or
choose 'Small' (eight output faders) mode when access to input faders must be retained at all times. Frequency
bands can be scrolled in banks of four or eight bands, using the Output Fader page buttons.
Set Delay Units
Change the units used in input, output, and monitoring delay adjustments.
You can choose between milliseconds, metres, or feet and inches.
EQ bandwidth units
Choose the unit for bandwidth controls in the EQ sections throughout the console
Selected either Octaves or Q-factor (defined as the ratio of frequency to bandwidth). The direction of the control
is reversed between the two settings: In Q mode, clockwise narrows bandwidth, in Octaves mode, clockwise
widens bandwidth.
Enable NEXT and LAST
Enable the [NEXT] and [LAST] cue list navigation buttons nearest the operator.
DSP Configuration
Set the console's DSP sample rate.
You can choose 48kHz (128 input channels) or 96kHz (64 input channels). Press {SET} to confirm a change.
NOTE: Changing the sample rate will reset the console and you will lose unsaved changes. A warning/confirma-